Temperature Test of CSE-H25
CSE-H25 is a new external serial device server, and it will be introduced soon.
This model is developed with durability under extremely low and high temperature.
The standard of the industrial temperature range is from -40℃ to 85℃
This test was implemented under the conditions and the humidity was variable in high temperature.
In July second, we test the matter at the Small and Medium Business Administration in In-Cheon, Korea.
The test was lasting for six hours.
Test Items
* Confirm the PING Reply in 500 times without any losses
* Confirm the TCP connection
* Confirm if the product can be searched by ezManager
* Confirm the data communication without any losses
* Check above items after the product reboots
Test Circumstances
* -40℃ (with no humidity)
* 85℃ (with 10% humidity)
* 85℃ (with 95% humidity)
Test Result
* All the items are satisfied under all the circumstances.
CSE-H25 works well under the industrial temperature range.







Posted by Roy