Review of CIE-M10

Review of CIE-M10

 

CIE-M10, embedded remote I/O controller has been introduced!

User image
 

Specification

* Remote Monitor and Control digital Input/Output Port

* Modular Type

* 10/100Base-T Ethernet, auto MDI/MDX

* 8 Digital Input Ports (3.3V CMOS)

* 8 Digital Output Ports (3.3V CMOS)

* 1 Analog Input Port (10 bits resolution ADC)

* UART x 1 (up to 230,400bps, UART <--> TCP/IP converting function)

* Supports uploading user’s web pages

* Security function: IP filtering, Password

* Built-in Web Server for simple management

* Supports Stand-Alone Operation and simple logical expressions

* Supports Modbus/TCP

* Flexible configuration and network communication by 'AT Commands' (patent)

* Supports communication with variety of TCP/UDP hosts (TCP Server/Client, UDP)

* Variety of communication status chekup (debugging mode, ezManager, Telnet)

* Supports DHCP and PPPoE for xDSL and cable network

* Supports 'DNS' protocol for simple connection to the Internet

* Supports Dynamic DNS (DDNS): available as Server with dynamic IP environment

* IP Change Trap feature: useful with dynamic IP environment

* Telnet COM Port Control Option (RFC 2217)

* Easy configuration utility via network for Windows OS (ezManager)

* Virtual COM Port Redirector 'ezVSP' for Windows OS (provided free of charge)

* Firmware is upgradable through network

* Environmentally-friendly RoHS compliant

 

CIE-M10 has all the options and functions of CIE-H10.

It can be controlled by HTTP, Modbus/TCP, serialized Modbus/TCP and Macro.

The model supports useful functions like DDNS, TCP/UDP notification of changed IP address.

 

This model also uses ezManager as a configuration tool like CIE-H10.

Look at the following picture.

 

User image

The Modbus/TCP test program will be created on your screen, when you select the products.

 

The product has one ADC port as well as 8 ports digital Input and Output.

This can be remarkable issue.

If the analog signal inputs the port, the values are presented the number between 0 and 1023. (10 bits resolution)

Users not only can configure the range of the values by using their HTML files but monitor.

 

User image

The examples of HTML are followed


<Default_image>

User image



<No_Comment>
User image


<Simple Image>

User image



<Simple Text>
User image



<Sample_01>
User image



<Sample_02>
User image



<Sample_03>
User image



In addition, because this model is formed of SMD type, the dimension is very small. So, you can easily apply to your system.

 

A LED which is connected with the first digital input port (Di0) is equipped for developer.

 

User image

Download All the skins of HTML

이올린에 북마크하기(0) 이올린에 추천하기(0)

Posted by Roy

2009/07/02 11:56 2009/07/02 11:56
, , , , , , , , , ,
Response
0 Trackbacks , 0 Comments
RSS :
http://blog.eztcp.com/ensollae/rss/response/22

Trackback URL : http://blog.eztcp.com/ensollae/trackback/22

Leave a comment
[Login][OpenID?]
You have to log in with and OpenID to leave a comment.

Using CIE-H10 as a Wireless LAN I/O Controller Ⅱ


CIE-H10 can be operated on Wireless LAN with CSW-H80.
CSW-H80 is a serial to Wireless LAN converter.
To use this, CIE-H10 has to be set to "Serial Modbus/TCP" mode.
This mode is a serialized Modbus/TCP mode.
In this mode, CIE-H10 receives Modbus/TCP data from RS232 Port.
So, we shold connect the CIE-H10 with CSW-H80 thgouth RS232 cross cable.
Or, it is okay to connect pin #2 (RXD), #3 (TXD) and 5(GND).
(RXD)  #2 ---------------- # 3 (TXD)
(TXD)   #3 --------------- # 2 (RXD)
(GND)  #5 --------------- #5 (GND)

Used devices & program
- CIE-H10
- CSW-H80
- AP:G104M (EFM networks)
- ezManager(v2.0j)

We used ezManager v2.0j on this test because the Modbus/TCP test program of new ezManager v.3.0a could not manually input peer IP address.
It's just an exmple.
So, you can try it any Modbus/TCP client.

System Scheme (Real)

User image

System Scheme (Abstract)
User image
Configuration
- CIE-H10
User image
- CSW-H80
User image
- Modbus/TCP Test program
User image
Pictures of the Test
User image

User image
User image
User image
Details of Configuration on each device

Division CSW-H80 CIE-H10 Modbus/TCP Client AP
Local IP Address 10.16.0.80 10.16.0.10 · ·
Local Port 502 · · ·
Peer IP Address · · 10.16.0.80 ·
Peer Port · · 502 ·
ezTCP mode T2S Serial Modbus/TCP Active ·
Serial Type RS232 RS232    
Baud Rate 115,200 115,200 · ·
SSID sollae · · sollae
이올린에 북마크하기(0) 이올린에 추천하기(0)

Posted by Roy

2009/06/02 06:14 2009/06/02 06:14

Trackback URL : http://blog.eztcp.com/ensollae/trackback/16

Leave a comment
[Login][OpenID?]
You have to log in with and OpenID to leave a comment.

[CIE-H10] F/W 1.3B has been released!

As we know, F/W 1.3A of CIE-H10 had been released a month ago. However, there is a bug that the home page doesn't work when it use brace '(' or ')' in the script. This problem has been solved with new F/W.

In addition, here is another example which is based on text.

User image


이올린에 북마크하기(0) 이올린에 추천하기(0)

Posted by Roy

2009/05/21 06:06 2009/05/21 06:06
, , , , , , , , ,
Response
0 Trackbacks , 0 Comments
RSS :
http://blog.eztcp.com/ensollae/rss/response/12

Trackback URL : http://blog.eztcp.com/ensollae/trackback/12

Leave a comment
[Login][OpenID?]
You have to log in with and OpenID to leave a comment.

CIE-H10's I/O Ports

1. Overall 


CIE-H10 is a device that monitors and controls the 8 digital input and output ports with TCP/IP. Each Port is monitored and controlled by Modbus/TCP and HTTP. CIE-H10 outputs port information to its output ports after calculating the pre-defined algebraic equations (Macro) according to input ports’ values. In addition, you can make them operate as an Internet Switch by using two CIE-H10s.

Input ports and output ports are not operated same way. There are a lot of questions that if the input and output ports are dependently operated each other. This technical document is for description of form and performance of the input ports and notification of the easy way to practical use with CIE-H10 as shows an example.

2. Digital I/O Ports
  a. Independence of I/O ports

  Table 21 Names of I/O ports of CIE-H10

Division

1

2

3

4

5

6

7

8

Input ports

DI 0

DI 1

DI 2

DI 3

DI 4

DI 5

DI 6

DI 7

Output ports

DO 0

DO 1

DO 2

DO 3

DO 4

DO 5

DO 6

DO 7

 User can easily think that the input and output ports are connected, because the number of input and output ports are same. An example is that the DI 0 forwards its signal to DO 0. Actually, this is possible by using the Macro option. However, CIE-H10 is not operated only this way. I hope to say that it is just only one case. The numbers on the table 2-1 are just named to distinguish each port and the ports are independently operated. For help to understand this, we’ll look into the Input and input ports in next chapter.

  b. Input Ports
 8 input ports of CIE-H10 are isolated with photo coupler interface. Photo coupler is element transfer electric input signal to its output ports using the light. Between the input ports and output ports are completely isolated. This is used for the case like forwarding signal between two circuits with different voltage level. This means CIE-H10’s input ports are received electric signals and decide between 0 and 1. Thus, it is impossible that set the ports to high with normal switch which didn’t have any voltage difference. Form of the each input port is shown in Fig. 2-1.


User image
Fig.
2‑1 Form of an input port of CIE-H10

 

In figure 2-1, [EXTERNAL INPUT 1] and [EXTERNAL INPUT 2] are parts of interfacing with user device.

We know input ports need voltage difference. If so, can we input a signal with 100 volt to the ports? What is the basis for deciding between 0 and 1? Maximum value of input ports is 24 V and CIE-H10 decides the signal as 0 in case of lower voltage then 1.2V and decides as 1 in case of higher voltage then 1.8V. Input ports are terminal blocks with 5mm spaces, so user can use them with screwdriver of (-) shape.

 

Table 2‑2 Voltage of input ports

Max Input Voltage

DC 24V

Input Voltage(H)

Min 1.8V

HIGH

1

Input Voltage(L)

Max 1.2V

LOW

0

 

CIE-H10 recognizes input port signals that last for [Valid Time] which is set by user. If the signal is not maintained for the time, the input signal will be ignored.

This [Valid Time] is used for Modbus/TCP, Macro, HTTP and other functions provided by CIE-H10. The unit of [Valid Time] is 1 millisecond. However, since the accuracy is only guaranteed in 10 ms, the designated values will round down in units of 10 ms according to the values set by the users.

ex) 15 ms -> 10 ms, 31 ms -> 30 ms

  c. Output Ports

Output ports of CIE-H10 consist of relay. This is a switch. This means the output ports do not make any signal with voltage difference but connect or disconnect the terminal so as to turn on/off their devices. Therefore a device needed to be supplied power does not work even though it is connected with output ports of CIE-H10. The making of output ports is followed.

 

User image

Fig. 2‑2 Form of an output port of CIE-H10

 

As see the figure 2-2, [EXTERNAL OUTPUT 1], [EXTERNAL OUTPUT 2] are parts interfaced with user’s devices. These are made of terminal blocks same as input ports, so you could use of this with screwdriver a (-) shape.

The output port functions as short or open circuit like a switch. Thus, devices needed to be supplied power have to be provided voltage input irrespective of CIE-H10’s power. Because the output ports just connect or disconnect two wires. In values of output ports, 0(OFF) means open circuit, 1(ON) means short circuit. A permissible range of current in each output port’s condition is followed.

Table 2‑3 Voltage of input ports

Condition

DC 28V

AC 125V

AC 250V

Permissible current

5A

10A

5A

 

Values are reflected in the output ports after delayed as optional time. Besides, the signal has to be maintained for [Delay] time. If it’s doesn’t, CIE-H10 does not recognize the signal as valid input. However, in case of setting [Delay] to 0, CIE-H10 operates its output ports right after the input signal is detected. The unit of [Delay] is 1 millisecond. However, since the accuracy is only guaranteed in 10 ms, the designated values will round down in units of 10 ms according to the values set by the users.

3. Practical use of CIE-H10
  a. A Device of detecting and controlling digital I/O
  CIE-H10 is a device of detecting and controlling digital Input and output remotely. User can make this by using Modbus/TCP and HTTP (Web). There are so many application examples of CIE-H10 like Internet Switch. Let’s make sure functions of CIE-H10 with an example in this paper. This example may help users to understand the product easily.

b. The Diagram

 

User image

그림 31 The diagram of this example

 

We’ll know about the functions of input and output ports. Stuffs used this experiment are listed on the table 3-1.

Table 3-1 Stuffs used the experiment

Stuffs

pieces

Purpose

CIE-H10

1

For the experiment

CSW-H80

1

For checking that power is supplied

Sensor

1

For input to the input port

Power Supply(5V)

3

For supplying power to each device

Outlet

1

For checking that output port is working

 

Look at the figure 4-2. A difference of voltage caused by the sensor being operated as input signal in first input ports named Di 0. This signal has been maintained for [Valid Time] and then, CIE-H10 has recognized the signal as valid input. Using Macro option, the last output ports named Do 7 has been connected automatically. In case of open circuit, (+) wire of the outlet is disconnected, so any devices plug in the outlet would be not supplied power. However, in case of short circuit, (+) wire is connected, so a device plug in the outlet would be supplied power.

Macro option allows users to control the output ports by simple Boolean Algebra. This experiment uses ‘Di 0 = Do 7’, line of Boolean Algebra. This line means if there is an input signal on Di 0, set Do7 to connect. For more information about the macro function, please refer to the user’s manual.

 

In the outlet of figure 3-2, CSW-H80 device for converting serial to wireless LAN has been connected to check if the output port works on. In the situation of recognizing valid input, CSW-H80 would be supplied power and turned on the PWR LED.

 

User image

Fig. 32 Overall of the experiment

 

 

User image

Fig 33 A Parts of inout ports


User image

Fig 34 A parts of outlets and its wire


User image

Fig. 35 Status of full connecting

User image

Fig. 36 A parts of the CSW-H80


  Look at the figure 3-6. In input and output LEDs of CIE-H10, the first input port (Di 0) and the last output port (Do 7) are turned on. As I mentioned above, this could be handled by user with macro option. This figure shows that CSW-H80 is supplied power through the outlet.

이올린에 북마크하기(0) 이올린에 추천하기(0)

Posted by Roy

2009/04/02 10:49 2009/04/02 10:49

Trackback URL : http://blog.eztcp.com/ensollae/trackback/4

Leave a comment
[Login][OpenID?]
You have to log in with and OpenID to leave a comment.

블로그 이미지

SOLLAE SYSTEMS ENGLISH BLOG

- Roy



Notices

Archives

Recent Comments

Recent Trackbacks

Calendar

«   2010/03   »
Sun Mon Tue Wed Thu Fri Sat
  1 2 3 4 5 6
7 8 9 10 11 12 13
14 15 16 17 18 19 20
21 22 23 24 25 26 27
28 29 30 31      

Site Stats

Total hits:
19079
Today:
10
Yesterday:
76